Description, Generator output, Electrical receptacles – JLG Workstation in the Sky-Boom Lifts User Manual
Page 76: Accessory ratings, Safety precautions, General, Preparation and inspection, Description -2, Generator output -2, Accessory ratings -2 safety precautions -2
SECTION 3 - SKYPOWER™ (HYDRAULICALLY DRIVEN)
3-2
– JLG Accessory Manual –
3124242
DESCRIPTION
This hydraulic-driven generator supplies AC power to the platform to power
tools, lights, cutting and welding equipment through an AC receptacle. All
power regulation components are located in a watertight box that is con-
nected by cable to the generator. The generator supplies power when run-
ning at the specified speed with the power switch on (switch is located on
platform). A three-pole, 30 Amp circuit breaker protects the generator from
overload.
Generator Output
Engine Speed of 1800 rpm +/- 10%.
ANSI Specs:
3-phase, 240-volt, 60Hz, 7.5kW
1-phase, 240/120-volt, 60Hz, 6kW
CE Spec:
3-phase, 400-volts, 60Hz, 7.5kW
1-phase, 220-volt, 50Hz, 6kW
Electrical Receptacles
GFI receptacle will be available for both ANSI and CE machines.
ACCESSORY RATINGS
SAFETY PRECAUTIONS
General
READ AND UNDERSTAND THE OPERATORS MANUAL FOR THE SPECIFIC JLG MODEL
BEING USED.
DO NOT OVER PLATFORM.
1. Make sure no personnel are beneath platform.
2. This factory installed option is available only on models specified.
3. Keep lanyard attached at all times.
4. Do not use electrical tools in extremely wet conditions.
5. Use correct voltage for tool being used.
6. Do not over load circuit.
PREPARATION AND INSPECTION
Ensure generator is secure, check condition of belt and wiring.
Model
Drive -Type
Generator Speed
1350SJP
1200SJP
Hydraulic
3000rpm (50 Hz)
3600 rpm (60 Hz)