background image

SECTION 3 - MACHINE CONTROLS

3-8

– JLG Lift –

3121321

Ground Control Descriptions:

1. Platform/Ground Select - This three way keyswitch is

used to select between platform controls or ground con-
trols. When in the center position, the machine is dis-
abled.

2. Engine Start Switch - Toggle Switch used to start engine.

3. Emergency Stop Button - Button, when depressed, will

immediately shut the machine off. Cuts out all functions
except emergency platform lowering.

4. Outrigger Select Switch - Toggle Switch used to select if

outriggers auto leveling function is active or not.

5. Platform Lift/Lower Switch - Toggle switch used to raise

and lower platform.

6. Deck Extend/Retract Switch - Toggle switch used to

extend and retract platform deck extension.

NOTE:

The platform deck extension should be retracted before
lowering the platform.

7. Glow Plug LED - This Yellow LED is off under normal

operating conditions. The LED is illuminated when the
ignition is on and the temperature sensing requires pre-
glow.

NOTE:

Do not start machine when Glow Plug LED is illuminated.
Once the LED goes out, machine starting is permitted.

8. Battery Disconnect Switch - Disconnects ground control

panel from the battery.