Switching to default network parameters, Static ip address, Acoustic signalling and keypad configuration 3.1 – 2N Helios IP User manual, 1510 v1.11 User Manual

Page 43

Advertising
background image

Acoustic Signalling and Keypad Configuration

3.1

43

Disconnected from LAN, IP address lost
whenever the UTP cable is disconnected from 2N

®

Helios IP, this

status is signalled by this tone combination.

Invalid telephone number or invalid unlocking code
you can dial an extension telephone number or enter the door-
opening code using the keypad. An invalid code is signalled by
this tone sequence.

Switching to default network parameters
after power up, a 30-second timeout is set for entering the
resetting code. For switching to default network parameters refer
to the Switching to Default Network Parameters – Static IP
Address
and Switching to Default Network Parameters – Dynamic
IP Address
subsections.

Call end signalling
a time limit can be set after which your call will be terminated. To
prolong a call, push a VoIP telephone key. The time limit is set
due to protection against call blocking.

Connected call for VoIP phone-to-2N

®

Helios IP calling

a short tone is played to signal call connection.

Table 3.1 List of Tone Signals

Switching to Default Network Parameters

– Static IP

Address

Switching to the default network parameters with the static IP address can be
performed in two ways. Either through a web interface as described in the Network
subsection or by pushing a combination of the quick dialling buttons as shown in
Figures 3.1–3.3. Upon resetting, the web server is automatically switched on if
switched-off before. The buttons have to be entered within 30 seconds after the
internal application launch as signalled by the

tone sequence. The maximum

delay between the buttons is 2 s.

Figure 3.1 Switching to Default Network Parameters – Static IP Address (Part Nos. 9137130E,

9137130CE, 9137130CKE, 9137131E, 9137131CE, 9137131CKE)