2N TELEKOMUNIKACE a.s., www.2n.cz

®

IP address, port for SNMP traps – Recipient's IP address and IP port for SNMP
traps (default IP port = 162). Make sure that this item is completed to make the
SNMP process work properly.
Second IP address, port for SNMP traps – Second recipient's IP address and
IP port for SNMP traps (default IP port = 162). If this parameter is filled in, the
SNMP trap will be sent both to the primary and secondary IP addresses.
SNMP community – An SNMP community is the group that devices and
management stations running SNMP belong to. Default = public.
Number of used channels – Use these parameters to define the
maximum/minimum counts of active voice channels (VoIP, PRI ISDN). An SNMP
trap will be sent automatically whenever the defined value is exceeded.
Signal level – Maximum/minimum value of the received GSM/UMTS module
signal. An SNMP trap will be sent whenever the defined values are exceeded.
User boards – Activate/deactivate the positions to enable/disable monitoring of
board presence/absence. The CPU board monitoring is always on and cannot be
disabled.

PRI Gateway

Here find the hypertext link to the CPU web interface.

Caution

The SNMP service works only if the following conditions are met:
The SNMP service is licensed and allowed in the

section.

Management

The CPU access data are filled in correctly in the

section.

PRI gateway

The primary IP address, source port and

parameter are filled

community

in.