Black & white tables – 2N StarGate/BlueTower v5.7 User Manual

Page 138

Advertising
background image

138

2N TELEKOMUNIKACE a.s., www.2n.cz

®

GSM module, use G##, where ## is number of GSM module.
Tariff – use this parameter to specify the Tariff number.
Time from – set the beginning value of the time interval (hh:mm) for the
selected rule.
Time to – set the end value of the time interval (hh:mm) for the selected rule.
Day – define a day in the week on which the rule shall be applied (1= Monday,
…, 7 = Sunday).

Clip table structure:

Prefix

Company

Change
prefix

Delete
last

Out
group

Time
from

Time
to

Day

605205697%

1

0

129

00:00

12:00 1234567

605205697#% 4

1

9

12:00

24:00 1234567

605%

1

#31#

0

129

00:00

24:00 1234567

605%

2

+420

0

349

00:00

24:00 1234567

0605%

3

-#31#

0

59

00:00

24:00 1234567

608%

1

#31#+420 0

0

00:00

24:00 1234567

%

1

0

9

00:00

24:00 1234567

%

100

0

G10

00:00

24:00 1234567

%

101

0

G1

00:00

12:00 1234567

%

101

0

G12

12:00

24:00 1234567

Black & White Tables

Set the rules to disable routing for calls that failed to meet the set parameters before,
such as unconnected calls, short calls, rejected calls, and so on.

Advertising