4 network connection (rj45), 5 serial com interface (rs232) – ADS-TEC OPC7013/7015/7022 User Manual

Page 29

Advertising
background image

Industrial PCs OPC7013/7015/7022

© ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen

29

6.4

N

ETWORK CONNECTION

(RJ45)

If the drivers required for functioning are installed on the device, the control system may

be integrated in an Ethernet network supporting the 10/100 Mbit standard by using the
Ethernet 10/100BaseT network connector. Specifications of this network topology must be
observed in this case. You can install the drivers required for the network function from

the enclosed service CD, should they not be installed on the device.

PIN NUMBER

SIGNAL NAME

1

TX +

2

TX -

3

RX +

4

NC

5

NC

6

RX -

7

NC

8

NC

Pos : 30 /D atent ec hni k/Schnitts tell en/Seriell e Schnitts tell e C OM RS232/Serielle Sc hnitts tell e C OM (RS232) f ür OPC / I PC / C PC / PLC / OTC / ITC / VMT / M SA- Serie @ 1\ mod_1249303286408_6. doc @ 6104 @

6.5

S

ERIAL

COM

INTERFACE

(RS232)

The serial interface is also used for digital data transmission. The RS232 interface can be

connected by using a commercially available 9-pin SUB-D cable.

PIN NUMBER

SIGNAL NAME

1

DCD

2

RxD

3

TxD

4

DTR

5

GND

6

DSR

7

RTS

8

CTS

9

RI

Note:
This interface is not electrically isolated.

Pos : 31 /D atent ec hni k/Lauf wer ke/Exter ne Lauf werke/ Ext er ne Lauf wer ke für OPC 5112 / 5115 / 5117 / I PC 1100 / CPC / PLC / OTC / ITC / VMT-Serie @ 0\ mod_1158926656205_6. doc @ 563 @