2. Installation of the Switch

AirLive POE-FSH1008AT

User’s Manual

10

2.6 Cabling Requirements

For 100BASE-TX ports

The 8 RJ-45 station ports require Cat. 5 twisted-pair UTP/STP cable for connection. When

configuring within the 10/100 BASE-T cabling architecture, the cable distance should be

within 100m.

The following table summarizes the cable requirement for 10/100BASE-TX connection:

10BASE-T

100 ohm Category 3, 4, 5 UTP/STP cable

100BASE-TX

100 ohm Category 5 UTP/STP cable


Auto MDI/MDI-X function

The POE-FSH1008AT is equipped with Auto-MDI/MDI-X function, which allows you to use

straight-thru cable even when connecting to another switch/hub. Simply use the

straight-through cable for all types of 10/100BASE-TX connections, either to a PC or to a

networking device such as other hub or switch.

2.7 Connecting to Power

POE-FSH1008AT features a universal auto-select power supply unit, which allows a power

connection to a wide range of input voltages from 100 to 240VAC @ 50 ~ 60Hz.

To establish its power connection, simply plug the female end of the power cord into the

power connector on the rear of the switch and the male end of the power cord into a

suitable power outlet. Once you have correctly plugged in the power, you can then turn on

the Power Switch to activate the switch.

2.8 Reset to Default

When you forgot your IP or password, please use the reset button for the factory default

setting? Please take the following steps to reset the Web Smart Switch back to the original

default:

Step 1. Turn on the POE-FSH1008AT.

Step 2. Press and hold the reset button continuously for 10 seconds and release

the reset button.