Config window – trap server panel, Igure, Onfig window – AirLive WHP-1130 User Manual

Page 37: Erver panel

Advertising
background image

Note: Do not set all the stations in the Access Control table to Read only. Once this

is set and enabled, it will be impossible to modify the outdoor bridge. Should
this situation occur, you need to restore the outdoor bridge to the factory
configuration by using Kick Start (see FAQs for details).

To set a stations’ access right, enter a station’s IP address and password and choose
Read or Read/Write.

When a setting is made, click OK. Repeat the procedure for the next station. When
all settings are made, click OK in the configuration dialog box to make the changes
effective.

Config Window – Trap Server Panel
When the outdoor bridge is powered on, or an Ethernet port becomes active, an event
log will be generated indicating the time, the IP address of the reporting outdoor
bridge, and the event. You can view and save the event logs from the station as a
Trap Server.

To assign a trap server, click Trap Server.

Figure 21. Config window — Trap Server panel

Outdoor Bridge/Outdoor Bridge Solution

27