Routine maintenance – Autoquip DOUBLE PANTOGRAPH LIFT User Manual

Page 37

Advertising
background image

37


OIL REQUIREMENTS:

Change oil yearly or more frequently if it darkens materially or feels gummy or gritty. Check
oil for the presence of water, (oil will turn milky in color).Do not use hydraulic-jack oil,
hydraulic fluids, brake fluids, or automatic transmission fluid.

OIL RECOMMENDATIONS

Hydraulic lifts operate efficiently utilizing high quality oil products that are readily available
in all areas. These oil products contain additives that are desirable for optimum
performance of the equipment. Follow the recommendations below that apply to the
circumstances most similar to your installation.

Environment (Ambient Temperature)

Recommended Oil

Indoor locations with variable temperatures:
30 - 100 degrees F

5W30 or 5W40 Multiviscosity Motor Oil

Indoor locations with constant temperatures:
60 - 80 degrees F

SAE 20 Motor Oil

Outdoor locations: 30 - 120 degrees F

5W30 or 5W40 Multiviscosity Motor Oil

Outdoor locations: 10 degrees F below 0 to
100 degrees F

5W20 or 5W30 Multiviscosity Motor Oil

Cold Storage Warehouse: 10 - 40 degrees F

Contact local Autoquip Service Rep.

NOTE: Oils listed above are detergent type oil.

OIL CAPACITY

*Contractor Polyethylene Tank: Oil capacity is approximately: (5.5) gallons or (22) quarts.

*Vertical Steel Tank: Oil capacity is approximately: (10) gallons or (40) quarts.

*Large Vertical Steel Tank: Oil capacity is approximately: (12) gallons or (48) quarts.

*The oil level in the Contractor or Vertical reservoir should be 1” below the top of the
reservoir with the lift in the fully lowered position.







ROUTINE MAINTENANCE

Advertising