General maintenance, Motor connection diagrams, Figure 5: motor wiring diagrams – Autoquip DOUBLE PANTOGRAPH LIFT User Manual

Page 40: Hp and voltage full load amperages

Advertising
background image

40



The following should be referenced in connecting the standard heavy-duty motors to
power sources. Remember that heavy wire must be used all the way to the power
source.


MOTOR CONNECTION DIAGRAMS

MOTOR

5

4

6

CONNECT TO LINE

CONNECT TO LINE

7

1

3

9

2

8

3

2

1

9

6

4

7

5

8

MOTOR

208/230 V.

460 V.

3 PHASE

CONNECT TO LINE

CONNECT TO LINE

4

3

8

5

1

4

115 V.

230 V.

1 PHASE

5

INT.

CAP

MOTOR

1

2

5

INT.

CA

P

3

2

5

MOTOR

8

Figure 5: Motor Wiring Diagrams










HP and Voltage

Full Load Amperages

3 HP: 115 / 208 / 230V /60 CY/1PH
Vertical Motor (Not Super Torque)

115 V = 33.6 Amps

208/230V=16.8 Amps

5 HP: 230 V /60 CY/1 PH
Vertical Motor (Not Super Torque)

230 Volts = 24.5 Amps

5 HP: 208 / 230 V /60 CY/3 PH
Contractor Motor (Super Torque)

208 V=15.8 Amps

230 V=14.8 Amps

5 HP: 460 V /60 CY/3 PH
Contractor Motor (Super Torque)

460 Volts = 7.4 Amps

5 HP: 208 / 230 V /60 CY/3 PH
Vertical Motor (Super Torque)

208 V=16 Amps

230 V=15.2 Amps

5 HP: 460 V /60 CY/3 PH
Vertical Motor (Super Torque)

460 V=7.6 Amps

GENERAL MAINTENANCE

Advertising