MK-170 Tile Saw MaiNTeNaNCe

Motor Brush Change-out

Disconnect the tool before servicing and when changing accessories,

such as blades, bits, cutters, and the like.

When installing motor brushes, care must be taken to ensure the spring

end is straight before installing the Motor Brush Cap.

(A)

Disconnect the MK-170.

(F)

Install Motor Brush Cap and

tighten using a Flat Head

Screwdriver.

(B)

Locate and Remove One Motor

Brush Cap using a Flat Head

Screwdriver.

(D)

Clean the Motor Brush Housing

using a Q-tip.

(G)

Install the Second Motor Brush

(Repeat Steps B to F).

(C)

Remove Motor Brush Housing

Cover.

(E)

Align and install the new Motor

Brush.

waRNiNG