Blue Sea Systems 8378 DC 18 Position User Manual

Installation, Dc power distribution panel, Warning

Advertising
background image

Marine Electrical Products

DC Power Distribution Panel

PN 8378 / PN 3378 18 Position

Panel Specifi cations

Material:

0.125” 5052-H32 Aluminum Alloy

Primary Finish:

Chemical Treatment per Mil Spec C-5541C

Final Panel Finish:

Graphite color 2 part textured Polyurethane

Circuit Breakers:

15 Ampere AC/DC magnetic

65V DC/277V AC Maximum

Amperage Rating: All components are sized for 100 Amperes of

continuous current

Voltage Rating:

Panels are rated for 12 volts DC. Panels can be
upgraded to 24 volts with PN 8240, 18-32V DC
Voltmeter.

Voltmeter Rating:

8-16 Volt DC meter. Accuracy 3% of scale

Ammeter Rating:

0-100 Ampere DC meter. Accuracy 3% of scale

External Shunt:

50 Millivolt = 100 Ampere resistive manganin
element

Inches

Millimeters

Overall Dimensions: 14-3/4 x 7-1/2

374.65 x 190.50

The Purpose of a Panel

There are fi ve purposes of a marine electrical panel:
• Power distribution
• Circuit (wire) protection
• Circuit ON/OFF switching
• Metering of voltage and amperage (In panels with meters)
• Condition Indication (circuit energized)

Applicable Standards

• American Boat and Yacht Council (ABYC) Standards and

Recommended Practices for Small Craft sections: E-1, E-3, E-9.

• United States Coast Guard 33 CFR Sub Part 1, Electrical Systems.

Blue Sea Systems Inc.

Phone (360) 738-8230

425 Sequoia Drive

Fax (360) 734-4195

Bellingham, WA 98226 USA

E-mail [email protected]

www.bluesea.com

Document 6682 Rev.B

WARNING

@

It is not possible within the scope of these instructions to fully acquaint
the installer with all the knowledge of electrical systems that may be
necessary to correctly install this product. If the installer is not
knowledgeable in electrical systems we recommend that an electrical
professional be retained to make the installation.

@

If either the panel front or back is to be exposed to water it must be
protected with a waterproof shield.

@

The panels must not be installed in explosive environments such as
gas engine rooms or battery compartments as the circuit breakers are
not ignition proof.

@

The main positive connection must be disconnected at the battery post
to avoid the possibility of a short circuit during the installation of this
distribution panel.

Guarantee

Any Blue Sea Systems product with which a customer is not satisfi ed
may be returned for a refund or replacement at any time.

Useful Reference Books

Calder, Nigel, 1996:

Boatowner’s Mechanical and Electrical Manual,

2nd edition, Blue Ridge Summit, PA: TAB Books, Inc.
Wing, Charlie, 1993:

Boatowner’s Illustrated Handbook of Wiring,

Blue Ridge Summit, PA: TAB Books, Inc.

Related Products from Blue Sea Systems

PanelBack Insulating Covers
High Amperage Fuses and Circuit Breakers for positive feed wires
High Amperage Battery Switches
Terminal Blocks and Common Bus Connectors
AC and DC Voltmeters and Ammeters

1. Disconnect all AC and DC power

Before starting, disconnect the main positive cable from all batteries to

eliminate the possibility of a short circuit while installing the distribution

panel. Also disconnect the AC shore power cord from the boat to

eliminate the possibility of electrocution from AC wiring in the proximity

of the DC distribution panel.

2. Optional - Upgrading to 24 Volts

Remove and replace the existing 8-16V DC voltmeter with an

18-32V DC voltmeter (PN 8240). Connect the existing meter sense

wires to the new meter, Red Positive wire to + and Yellow negative wire

to

-.

3. Select mounting location and cut opening

Select a mounting location which is protected from water on the panel

front and back and is not in an area where fl ammable vapors from

propane, gas or lead acid batteries accumulate. The circuit breakers

used in marine electrical panels are not ignition protected and may

ignite such vapors.

Using the panel template provided, make a cut out in the mounting

surface where the distribution panel is to be mounted. Do not fasten

the panel to the mounting surface.

4. Select positive feed wire and negative return

Determine the positive feed (red) and negative return (black or yellow)

wire size by calculating the total amperage of the circuits that will be

routed through the panel. Blue Sea Systems’ electrical panels are

rated at 100 ampere total capacity. The positive feed wire must be

sized for 3% voltage drop at the 100 ampere panel rating or the

maximum amperage that will be routed through the panel in any

particular installation, whichever is less.

Installation

particular installation, whichever is less. It is recommended that the

positive feed wire be sized for the full panel capacity, which in most

cases, will require at least 2 AWG wire, assuming a 10 foot wire run

between the panel and the batteries in 12 volt systems. Refer to the

Wire Sizing Chart for other situations.

Remember that the length of the circuit is the total of the positive wire

from the power source and the negative wire back to the DC negative

bus. Be certain that there is a fuse or circuit breaker of the correct size

protecting the positive feed wire.

5. Install shunt, positive feed wire and negative return

The panel is supplied with an external shunt ammeter that must be

connected in the positive feed line to the panel. The shunt may be

mounted at any point in the feed line, but mounting it close to the panel

will keep the sense wires that run to the meter short, minimizing

voltage loss and interference, creating the most accurate meter

reading.

Connect the positive feed wire from the positive source to either of the

2 large bolt terminals on the shunt top. This is now the shunt positive

terminal. Connect two additional lengths of feed wire from the

remaining shunt terminal, now the negative terminal, to both panel

positive buses. Next, connect a minimum 16 AWG red wire from the

screw on the side of the shunt positive terminal to the meter positive

terminal and connect another identifi ng color wire from the shunt

negative terminal to the meter negative terminal. There should be a 1

ampere fuse in the sense wires near the shunt terminal. Be certain that

on all 4 shunt connections the wire ring terminals sit directly on the

brass blocks of the shunt without any washers in between.

Connect a negative return wire from both negative buses on the panel

to DC negative.