background image

CAUTION symbol refers to a potentially hazardous situation which, if not avoided, may

result in minor or moderate injury.

WARNING symbol refers to a potentially hazardous situation which, if not avoided, could

result in death or serious injury.

Instructions

WeatherDeck®

Waterproof Fuse Panels

PN 4302 / PN 4304 / PN 4306 / PN 4308

Blue Sea Systems Inc.

p 360.738.8230

425 Sequoia Drive

f 360.734.4195

Bellingham, WA 98226 USA

[email protected]

www.bluesea.com

6443 Rev.004

WARNING

CAUTION

Installation

GUARANTEE: Blue Sea Systems stands behind its products for as long

as you own them. Find detailed information at www.bluesea.com/about.

For customer service, call 800-222-7617.

Maximum Operating Voltage

12V DC

Maximum Operating Amperage

15A @ 12V DC (per circuit)

Backlight Operating Current (Amperage) 10mA/Illuminated Circuit

Panel Cumulative Rating

30A (PN 4302)

60A

(PN 4304)

90A

(PN 4306)

100A

(PN 4308)

Switch Rating

15A Maximum

Backlighting Voltage

12V DC Nominal

Fuse Rating

15A installed, others available

Material: Cover

UV Resistant Thermoplastic

Panel

UL-V0 Flame Resistant Thermoplastic

Regulatory

Waterproof IP67—Protected against immersion up to 1 meter for 30 minutes

Specifications

Specifications subject to change. See bluesea.com for additional information and specifications

Designed for open-cockpit and flybridge applications

• Includes 15A, ATO®/ATC® Fuse installed in each position
• Bicolored LEDs illuminate circuit labels to quickly identify OFF (Red),
ON (Green), or Blown (No color) circuits
• Backlighting is compatible with DeckHand Dimmers
• Independent label backlighting allows switching and dimming
• Integrated switch guards reduce the risk of accidental switching
• Panels can be mounted in four different orientations
• Panel front rated waterproof IP67 when properly mounted with the
watertight mounting gasket
• UV stabilized weather-resistant faceplate snaps on and off providing
access to components and concealing mounting screws
• Square Format Label Set 4215 included

DC

AC

1. Before beginning electrical installation, disconnect all AC and DC power sources.

2. Select mounting location and panel orientation away from flammable areas.

Panel can be mounted in any of the four orientations shown below.

WARNING

CAUTION

If you are not knowledgeable about electrical systems, consult an

electrical professional.

If the panel front is to be exposed to water, it must be properly sealed to the surface.

The included gasket must be in place and the panel screwed down securely.

Panel switches are not ignition proof—the panel must NOT be installed in an

explosive environment such as a gasoline engine room or battery compartment.

3. Cut opening with template provided.

WARNING

PN Positions

Voltage

Width

in (mm)

Height

in (mm)

Depth

in (mm)

Width

Mounting

Centers in (mm)

Height

Mounting

Centers in (mm)

4302

2

12V DC

3.88

(98.55)

2.60

(66.04)

2.50

(63.50)

3.31

(84.07)

2.04

(51.82)

4304

4

12V DC

3.88

(98.55)

4.30

(109.22)

2.50

(63.50)

3.31

(84.07)

3.74

(95.00)

4306

6

12V DC

3.88

(98.55)

6.00

(152.40)

2.50

(63.50)

3.31

(84.07)

5.44

(138.18)

4308

8

12V DC

3.88

(98.55)

7.70

(195.58)

2.50

(63.50)

3.31

(84.07)

7.14

(181.36)

®

Advertising