Comelit MT VIP SYSTEM User Manual

Page 12

Advertising
background image

12

1

2

3

4

5

6

Digital call module art. 3370

1.

Graphic LCD display.

2.

Search buttons.

3.

Call / select menu button.

4.

Search name / Exit menu button.

5.

Call / local door-opener button.

6.

Delete character / Pause call button.

Technical characteristics

Power supply

13 Vac

Temperature thresholds

-30 / +55°C

Dimensions

H: 18 cm W: 11.2 cm D: 4 cm

Digital call module complete with electronic directory with graphic LCD display. Also functions as a coded electronic key module. Names can be
scrolled using the two search buttons or by entering the initial letter of the required name. Once the right name has been found, press the call
button. The user code can also be entered to make a direct call.

1

1.

Terminal block for connection.

ViP system audio-video unit with terminal block, complete with spherical lens adjustable colour camera.

Audio / video unit art. 4662C

NC / NO:

Door lock connection terminals.

COM:

Common terminal.

DO:

Door Open terminal.

RTE / -:

Timed relay control terminals.

~ ~:

Power supply terminals.

TX- / TX+:

Ethernet transmission line terminals.

RX- / RX+: Ethernet reception line terminals.

Technical characteristics

Power supply

13 Vac

Temperature thresholds

-30 / +55°C

Dimensions

H: 10.2 cm W: 5.5 cm D: 3.5 cm

~ ~:

Power supply terminals.

PR -: Programming terminals.
TX RX: RS232 line terminals (not used).
-:

RS232 line negative terminal (not used).

D- D: RS485 data line.

N.B. Up to this point, the functions linked to the RS485 line have not
been implemented.

Advertising