Chapter 3: System preparation and specifications

A Max.

0.5 mm2 (Ø 0.8 mm - AWG 20)

10 m

0.5 mm2 (Ø 0.8 mm - AWG 20)

Comelit art. 4576-4578

10 m

1 mm2 (Ø 1.2 mm - AWG 17)

25 m

1 mm2 (Ø 1.2 mm - AWG 17)

Comelit art. 4577

25 m

1 mm2 (Ø 1.2 mm - AWG 17)

25 m

1.5 mm2 (Ø 1.4 mm - AWG 15)

40 m

2.5 mm2 (Ø 1.8 mm - AWG 13)

60 m

Connection distances from power supply unit art. 1395 to external unit art. 3331

1395

Connection distances between external unit art. 3331 and Switch art. 1440
The connection distance varies depending on the port used on Switch art. 1440.

Art. 1440

10 Mb

250 m

Art. 1440

100 Mb

120 m

Using the 10 Mb port

Using the 100 Mb port

Connection distances between 2 Switches art. 1440
The connection distance varies depending on the ports used on Switches art. 1440.

Art. 1440

10 Mb

250 m

Art. 1440

10 Mb

Art. 1440

10 Mb

250 m

Art. 1440

100 Mb

Art. 1440

100 Mb

250 m

Art. 1440

10 Mb

Art. 1440

100 Mb

120 m

Art. 1440

100 Mb

Connection distances