PROGRAMMING THE PUSHBUTTONS

FAULT INDICATION AND TROUBLESHOOTING

Select the “Program key button” icon using

pushbuttons

and confirm your selection by
pressing .

From the installer menu (pushbutton 1), enter the

“Buttons programming” menu using

and .

• KEY PUSHBUTTON

The kit has 2 relays (relay 1 and relay 2) for each
external unit connected.
Their operation may be programmed either during a
call or when the system is in standby.
When every pushbutton has been programmed for
relay control, a maximum of 2 relays* may be
activated at the same time.
In the event of a call, one of the relays activated
must correspond to the door from which the call is
made.

If there is no connection with the internal unit, wait for
1 minute. If the indication appears again, make sure:
• That the secondary monitor has the same address as

the main monitor for the relevant residential unit
(paragraph 14A).

• That the main monitor is receiving power (paragraph

11).

• That the correct password has been entered

(paragraph 14C and 20).

• That the installation distances have been observed

(paragraph 8).

If there is no connection with the external unit, make

sure:

• That the external unit is wired correctly (paragraph 2)

and that it is receiving power (paragraph 8).

• That the bridge Art. 1398 is wired correctly

(paragraph 7A, 7B, 7C).

• That the password for bridge Art. 1398 is the same

as the password for the power supply of the monitor
in the same residential unit.

• That the installation distances have been observed

(paragraph 8).

* If 2 relays are activated at the same time, provide
a special power supply for one of the loads.