CONDUX WINCH LINE BLOWER

14

5.

Remove the winchline blower assembly from the conduit by turning the winchline

blower body counter-clockwise until the unit can be removed from the duct.

6.

Set the winchline blower off to one side and out of the way.

7.

The missile and connector must be removed from the winch line at the exit utility

service access vault. The winch line can then be prepared to pull in the cable

assemblies or a mandrel, depending on job requirements.

!WARNING: Never attempt to pull back mandrels or cable with the winchline
blower assembly still installed in the conduit. Damage to the seal-off body
assembly or the conduit will result.

!CAUTION: Keep all components of the Winch Line Blower Kit clean and free of
all foreign materials.