Troubleshooting, Solutions to possible problems – Condux Winch Line Blower System User Manual

Page 23

Advertising
background image

CONDUX WINCH LINE BLOWER

21

4. Troubleshooting

Solutions to possible problems

!WARNING: DO NOT ENTER THE UTILITY SERVICE ACCESS VAULT TO CHECK
THE MISSILE OR SEAL-OFF WHILE THE SYSTEM IS UNDER PRESSURE. SHUT OFF
THE AIR SUPPLY AND DUMP THE RELIEF VALVE PRIOR TO ENTERING THE

UTILITY SERVICE ACCESS VAULT.

PROBLEM

SOLUTION

THREADED ADAPTER DOES NOT FIT

INOT THE CONDUIT.

1.

Wrong size threaded adapter was

selected

MISSILE GOES INTO CONDUIT A
DISTANCE BUT WILL NOT EXIT AT

OTHER END.

1.

If air is escaping at the exit end, the
air is bypassing the missile. The

missile is either worn out or is the

wrong size for the conduit in

which it is being used. The missile
will have to be pulled back out of

the conduit and replaced. Follow

the removal process for the seal-off

body assembly as listed in the
previous section and use the winch

truck to pull back the missile.

2.

If no losses are found at either end

of the conduit run, the missile may
have stopped due to a conduit

obstruction or due to an unsealed

conduit run. In the latter case, the

Condux Winch Line Blower will
not properly function. In this

instance,

the

seal-off

body

assembly must be removed from

the conduit as described in the
previous section, the missile must

be pulled back out of the conduit

by the winch line, and another

method of inserting the winch line
into the conduit must be used.

MISSILE GOES INTO CONDUIT A

DISTANCE BUT WILL NOT EXIT AT

OTHER END DUE TO A CONDUIT

1.

The Condux Winch Line Blower

will push water, sand, and small
gravel in front of the missile and

Advertising