Tear down procedures – Condux Gulfstream 200 Micro Fiber Blower User Manual

Page 15

Advertising
background image

15

Tear Down Procedures

!wARNINg: Air block Assembly contains compressed air when blower is
operated. opening Air block while under pressure may cause serious
personal injury. Ensure blower is depressurized before removing Air
block cover.

A. REmoVE PowER fRom uNIT

1. Turn off compressed air by closing the Air Control Valve at the blower.
(See figure 15). Shut off air at the compressor and decompress air hose.
Depressurize the air block by turning the air control valve counterclockwise.
(See figure 16). Remove air hose when system is relieved of pressure.

2. Raise Tractor Drive by turning down screw counterclockwise. (See figure 17).

3. Disconnect battery cable

b. REmoVE fIbER fRom bLowER

1. Loosen the knob on the Air Block assembly and open the air block.
(See figure 18).

2. Remove duct pack assembly.

3. Open duct pack assembly and remove the conduit.

figure 15. Turn off Air

figure 16. Depressurize Air block

figure 17. Raise Tractor Drive

figure 18. Loosen knob

8.

Advertising