Set up the blower – Condux Gulfstream 200 Micro Fiber Blower User Manual

Page 8

Advertising
background image

8

Set Up the Blower

This manual contains setup and operating instructions for the Gulfstream 200 micro
fiber blower.

A. DETERmINE fIbER SIZE
Determine size of fiber to be installed. To provide optimal traction and grip, if fiber
diameter is 1.5mm or less, the top belt of blower must be changed to a flat belt which
is included in the common parts kit. This flat belt is to be used in combination with the
bottom grooved belt, so that adequate contact and proper push force can be applied
to the fiber. Refer to Section 9 for belt replacement instructions.

b. SELECT CAbLE SEAL & DuCT PACk
Choose the correct cable seal and duct pack for the particular application according to
duct and cable size. Refer to Cable Seal and Duct Pack selection charts.

5.

CAbLE SEAL SELECTIoN

CAbLE oD (mm)

CAbLE SEAL kIT PN

DuCT PACk PN

0.8-1.5

08783074

08783051; 08783052; 08783053

1.5-2.0

08783057

08783051; 08783052; 08783053

2.0-2.5

08783058

08783051; 08783052; 08783053

2.5-3.0

08783064

08783051; 08783052; 08783053

3.0-3.5

08783059

08783051; 08783052; 08783053

3.5-4.0

08783060

08783052; 08783053

4.0-4.5

08783061

08783052; 08783053

4.5-5.0

08783062

08783052; 08783053

5.0-5.5

08783063

08783052; 08783053

DuCT PACk SELECTIoN

DuCT oD (mm)

DuCT PACk PN

5.0mm

08783051

7.0mm

08783051

8.0mm

08783052

8.5mm

08783052

10.0mm

08783052

12.0mm

08783053

12.7mm

08783053

Advertising