Technical Information

A. CoNDITIoN of uSE:
Temperature from 21° F (-6° C) to 110° F (+43° C) Humidity from 30% to 90% +/- 5%,
Weather conditions relevant to working conditions, Natural and/or artificial lighting of
the work site, minimum 200 lux.

b. AIR ComPRESSoR REquIREmENTS

1. Pneumatic Pressure: 175 psi (12 bar) Maximum
2. Required Air Flow: 5 - 15 CFM (.14 - .42 m3/min)
3. Conduit Size: 5mm – .50" (12.7mm) OD
4. Air hose fittings: ¼" Quick Connect


C. oPERATIoNAL CAPACITIES

1. Pushing Force: 10lbs (45N) Max Push Force
2. Pushing Speed: 165 ft/min (50 m/min) Maximum
3. Cable Sizes: 0.8mm to 5.5mm
4. Conduit Sizes: 5mm, 7mm, 8.5mm, 10mm, 12mm, 12.7mm (

1

2

")


D. ELECTRICAL REquIREmENTS:

1. Power Requirements: 12Volt (10.8V) DC @ 5Amp Max
2. Power Consumption: 60 Watts Maximum
3. Power Connection: Supplied Battery Pack (includes battery charger)


E. PhYSICAL SPECIfICATIoNS

1. Height 4.6" (117 mm)
2. Length 7.5" (190 mm)
3. Width

6.0" (152 mm)

4. Weight 5.7 lbs (2.6 Kg)


f. CATERPILLAR DRIVE SPECIfICATIoNS

1. Pushing Force: 10lbs (45N) Max Push Force
2. Pushing Speed: 165 ft/min (50 m/min) Maximum
3. Maximum clamping force: <12 lbf/in (2.1 N/mm)
4. Constant cable centerline design
5. Forward and reverse
6. Independent pushing drive belts with molded urethane cover profiled

for cable 0.8mm to 5.5mm

7. Slide guards

g. CoNDuIT CouPLINg REquIREmENTS

1. Must withstand maximum air pressure of 175 psi (12 bar)
2. Must withstand axial loading and vibration
3. Must be screw type, compression type, or fusion type
4. Sight holes must be sealed
5. Must fit snugly
6. Conduit ends must be cut off squarely and deburred
7. Conduit must be fully seated into the coupler
8. Couplers should be installed in a straight section of conduit
9. Must be same size conduit

2.