3 main power, auxiliary power, Main power, auxiliary power – ElmoMC ExtrIQ Gold Line Servo Drives-Gold Tiger User Manual
Page 29

Gold Tiger Installation Guide
MAN-G-TIGIG (Ver. 1.000)
||Main Power, Auxiliary Power
29
6.3 Main Power, Auxiliary Power
The Gold Tiger receives power from main and auxiliary supplies and delivers power to the motor.
Pin
Signal
Function
Cable
C
PE
Protective Earth
DC Power
B
VN-
DC Negative Power input DC Power
A
VP+
DC Positive Power input
DC Power
6-Pin Amphenol Male Connector
(D38999/20WE6PA)
6-Pin Amphenol Female
Connector
(D38999/26WE6SA)
Table 3: Connectors for Main Power
Optional Backup Supply in A, H, S, or T option drives.
Pin
Signal
Function
Cable
A, H, S, or T option type
14
VL+
+24 V Auxiliary Supply
Input Positive
DC Power
6
VL-
24 V RET Auxiliary Supply
Input Return
DC Power
15-Pin D-Type Male Connector
15-Pin D-Type Female
Connector
Table 4: Auxiliary Power Connector