Single-Phase Direct-to-Mains Connection Topology

Figure 15: Non-Isolated Single-Phase Connection Topology

The Power Supply is connected directly to the mains AC line.

Warnings:

Do not connect VN- to PE. In a direct-to-mains connection the VN- must not

be connected to the PE, as this will cause irreparable damage to the system.

Take care and note that in a direct-to-mains connection the Neutral point is

not the most negative voltage level. It is the mid-point level of the rectified

DC bus.