3 sto, 1 source mode plc voltage level, 2 ttl mode ttl voltage level – ElmoMC ExtrIQ Gold Line Servo Drives-Gold Tiger User Manual
Page 46
Advertising
![background image](/manuals/558369/46/background.png)
Gold Tiger Installation Guide
MAN-G-TIGIG (Ver. 1.000)
||Port C, Analog Input, and STO
46
6.6.3
STO
The following circuits describe the STO wiring options.
6.6.3.1
Source Mode PLC Voltage Level
Figure 29: STO D-Type Input Connection – PLC Source Option
6.6.3.2
TTL Mode TTL Voltage Level
Figure 30: STO Input Connection – TTL Option