Installation, Power and data cabling requirements, Power – ETC Selador Series CE User Manual

Page 12: Data, Power data

Advertising
background image

7

Selador Series User Manual

Installation

Power and Data Cabling Requirements

Power

The Selador series fixture operates on AC power, 100 to 240VAC/50-60Hz. You may use

a circuit powered through an SCR dimmer, as long as the dimmer is set to unregulated

non-dim (switched) operation.

Power is supplied through a standard 1.5m power-input cable with Neutrik PowerCon

locking pigtail with bare ends for attachment of your desired connector.

Data

The Selador series fixtures operate on a DMX control signal. The unit is supplied with a

5-pin XLR DMX input connector and a 5-pin DMX Thru connector. DMX cables should be

acceptable for DMX data transmission (not microphone cable) and should follow the

standard pinout. The optional secondary data pair is not used by the Selador series fixtures.

The maximum DMX data run from any DMX source to the last fixture in a chain is 300m.

Termination is required in the data thru port of the last fixture in each data chain.

See

Control, page 13

for additional information on DMX addressing of Selador Series

fixtures.

DMX512 pinout for five-pin XLR female

1

Common (Shield)

2

Data –

3

Data +

4

not connected

5

not connected

Push

1

2

3

4

5

Advertising