Connections and addressing, Fuse – ETC Selador Series CE User Manual

Page 17

Advertising
background image

12

Connections and Addressing

Connect AC input power and DMX data cables to the appropriate ports as shown below.

Connect the incoming DMX data cable to the DMX Input connector. If you are

daisy-chaining the data to other fixtures or DMX-controlled devices, connect the next DMX

cable to the DMX Thru connector. The Selador Series fixtures require that the last fixture

on a DMX line be terminated with a 120

 resistor between pins 2 and 3.

Connect the AC Input cable:

Align and insert the power connector. Twist the connector clockwise until it locks into place.

Disconnect the AC Input cable:

Slide back the locking tab, twist the connector counterclockwise and pull to unlock and

disconnect the power connector.

Fuse

The quarter-turn fuse-holder requires a straight blade screwdriver to remove and reinstall

a fuse. Refer to

Fuse Capacities, page 16

for information about fuse types.

DMX Thru

Power

DMX Input

Addressing

Fuse

Data connections

Addressing and fans repeat per cell

Power connection

and fuses

Advertising