Installation Procedures

Installing Mounting Hardware

Four different options are provided for mounting Selador fixtures.

Yoke for 11 and 21 fixtures

Double yoke for two 11 or two 21 fixtures (over/under configuration)

Floor trunnions for all fixtures

Pipe hanging brackets for all fixtures

N o t e :

Trunnions should be installed with the feet inward so that fixtures can be lined up end to

end if needed.

Installation Notes

Cooling and Duty Cycle

Selador Series fixtures are equipped with ultra-quiet cooling fans. These fans are

automatically controlled. They permit fan-free operation when possible and turn on only

when needed to provide low-noise, predictable service for extended periods of time in

ambient temperatures up to 40°C. When the fan turns on, its speed ramps up slowly in

order to minimise the noise differential.

C A U T I O N :

Duty Cycle

Operating the fixtures in higher ambient temperatures or low airflow situations may

cause the power supply to shut down. Following a cool down period, the power

supply will automatically reset and the fixture will return to operation.

It is good practise to power down any device with on-board electronics to limit

unnecessary wear on the devices and eliminate residual use of electricity. When

not in use, Selador fixtures should be powered down by disconnecting from power

either at the breaker or by unplugging.

LED life is adversely affected by high temperature operation. Whenever possible, avoid

turning all channels to 100% for extended periods, such as channel checks or focusing.