Operating Instructions for Rope Pull Switches
RPS...


Electrical connection


Electrical connection must be performed only by authorized personnel.

Connection of RPS…

1.

Release cover using a screwdriver

2.

Open break-out wall by screwing in the cable

gland, remove the plastic part

3.

Tighten cable gland

4.

Connection to cage pull spring

5.

Insert screwdriver (2.5 mm blade width) (1) into

bottom opening

6.

Turn screwdriver by 45 (2)

7.

Insert flexible cable with a cross-section of 0.08 ...

1.5 mm² in the upper opening (3)

The cable end must be fitted with a wire end
ferrule.

8.

Remove screwdriver

9.

Press on cover

Connection of RPS-M…

1.

Remove cover. To do this, unscrew the cover

screws with a screwdriver and remove the cover.

2.

Electrical connection. The electrical contacts of

the switches have M3.5 screw terminals. For the
terminal assignment, see section “Circuit symbol
and switching diagram”.

The connection must be made as stranded wire
with wire end ferrule or as a single wire with the
conductor cross sections 0.5 … 1.5 mm².

3.

Close cover. Place the cover on the housing as

shown and tighten the cover screws with a
torque of 2 Nm.