Operating Instructions for Rope Pull Switches
RPS...

Installation sequence

Installation must be performed only by authorized personnel.

1 A

1.1A

1.2A

1.3A

Attach bearing element with tensioner spring; fit pull rope: sheathing must be removed in clamping area; insert rope
in the fast-action clamping head as shown and secure.

B

1.1B

1.2B

Attach bearing element with counterspring; fit pull rope: secure rope as shown with thimble and rope clamp, attach
rope bridge to limit travel of counterspring with thimbles and rope clamps.

2

2 - 5 m

La = 150 mm

rope tension

Observe distance to the 1st support point. The 1st rope support next to the switch must be installed after La =150
mm.
Install supports at intervals of 2 – 5 m.

3

Fasten the RPS switch with four M5 screws
(also M6 for RPS-M) .

Maximum tightening torque M = 2 Nm.

The emergency stop switches must be
positioned so that the rope or emergency stop
slam button can be reached without obstacles
in hazardous situations.

17

85,5

72

40

48

10

Display

Display

8

Advertising