Operating instructions for rope pull switches rps – EUCHNER RPS User Manual
Page 7

Operating Instructions for Rope Pull
Switches RPS...
7
When installing and adjusting the rope pull switch, it is necessary to take into account the physical changes in
the rope length as a result of variations in temperature.
Table 3 shows the permitted rope tension lengths as a function of the expected temperature difference.
The diagram also shows the maximum permitted rope tension length for the different spring forces of the
respective switch types. It also permits selection of the appropriate switch corresponding to the expected
temperature variations.
Table 3
Rope tension length Lmax. in meters [m]
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
55
60
65
70
75
+/-40 K
+/-35 K
+/-30 K
+/-25 K
+/-20 K
+/-15 K
+/-10 K
+/-5 K
Max. temperature
fl
uctuati
on i
n
Kelvin
+/-3.5 K
RPS...100
Rope tension length max. 25 m
RPS...175
Rope tension length max. 37.5 m
RPS...300
Rope tension length max. 75 m
Rope supports must be provided at intervals of 2–5 m when planning and installing the system. Refer also to
the section Safety precautions.