Technical data
Version
RPS…
RPS-M…
Electrical data
(refers to the switch without plug connector)
Rated insulation voltage
U
i
250
V
Rated operating voltage
U
e
240 V
Rated impulse withstand voltage
U
imp
2.5 kV
Continuous thermal current
I
the
10
A
Utilization category
AC 15; 230 V/ 3 A
AC 15; 240 V/ 3 A
DC 13; 250 V/ 0.27 A
Short circuit protection
6 A gG acc. to IEC 60269-1
Safety class
II
I
Positively driven NC contacts
IEC/ EN 60947-5-1, Appendix K
Pre-failure monitoring RPS-M-E…
Rated operating voltage
U
e
10-30 V/DC
Rated operating current
I
e
50 mA
Utilization category
DC 13
Short circuit protection
Yes
Reverse polarity protection
Yes
Connection
Screw terminal, 3-pin
= 1.5 mm²
Mechanical data
Housing/cover
PA 6 GV (UL94-VO)
die-cast aluminum
Emergency stop
PA, glass-fiber reinforced
Actuation
Die-cast zinc/steel
Ambient temperature
-25°C to +70°C
-30°C to +80°C
Contact opening gap
> 2 x 2 mm
Mechanical life
acc. to IEC 60947-5-5 1 x 10
5
operating cycles
Switching frequency
≤
20/min.
Latching device
acc. to EN 60947-5-5, DIN EN 418
Emergency stop reset
RPS...SC : By turning the RESET actuating cylinder
RPS...PR/PC: By pulling the blue RESET button
Rope length
acc. to type L
max
= 75 m / 37.5 m / 25 m (
observe Table 3
)
Rope
D =
2 - 5 mm
Rope attachment
RPS...SC/PC... Fast-action clamping device / PR... by
means of ring
Connection
8 x x cage pull springs 0.08
... 1.5 mm² flex.
8 screw terminals (М3.5)
Cable entry
3 x M20x1.5
Mounting
4 x M5
4 x M5 or 4 x M6
Weight
Approx. 0.65 kg
Approx. 1.0 kg
Degree of protection
IP67 acc. to EN 60529
Regulations
EN 60947-1, EN 60947-5-1, EN 60947-5-5, EN ISO 13850
EC conformity
See enclosed Declaration of Conformity
Approvals
c CSA us / BG