Electrical data

(refers to the switch without plug connector)

Rated insulation voltage

U

i

250

V

Rated operating voltage

U

e

240 V

Rated impulse withstand voltage

U

imp

2.5 kV

Continuous thermal current

I

the

10

A

Utilization category

AC 15; 230 V/ 3 A

AC 15; 240 V/ 3 A

DC 13; 250 V/ 0.27 A

Short circuit protection

6 A gG acc. to IEC 60269-1

Safety class

II

I

Positively driven NC contacts

IEC/ EN 60947-5-1, Appendix K

Pre-failure monitoring RPS-M-E…

Rated operating voltage

U

e

10-30 V/DC

Rated operating current

I

e

50 mA

Utilization category

DC 13

Short circuit protection

Yes

Reverse polarity protection

Yes

Connection

Screw terminal, 3-pin

= 1.5 mm²



Mechanical data
Housing/cover

PA 6 GV (UL94-VO)

die-cast aluminum

Emergency stop

PA, glass-fiber reinforced

Actuation

Die-cast zinc/steel

Ambient temperature

-25°C to +70°C

-30°C to +80°C

Contact opening gap

> 2 x 2 mm

Mechanical life

acc. to IEC 60947-5-5 1 x 10

5

operating cycles

Switching frequency

20/min.

Latching device

acc. to EN 60947-5-5, DIN EN 418

Emergency stop reset

RPS...SC : By turning the RESET actuating cylinder

RPS...PR/PC: By pulling the blue RESET button

Rope length

acc. to type L

max

= 75 m / 37.5 m / 25 m (

observe Table 3

)

Rope

D =

 2 - 5 mm

Rope attachment

RPS...SC/PC... Fast-action clamping device / PR... by

means of ring

Connection

8 x x cage pull springs 0.08

... 1.5 mm² flex.

8 screw terminals (М3.5)

Cable entry

3 x M20x1.5

Mounting

4 x M5

4 x M5 or 4 x M6

Weight

Approx. 0.65 kg

Approx. 1.0 kg

Degree of protection

IP67 acc. to EN 60529


Regulations

EN 60947-1, EN 60947-5-1, EN 60947-5-5, EN ISO 13850

EC conformity

See enclosed Declaration of Conformity

Approvals

c CSA us / BG

12