Operating instructions for rope pull switches rps, Switching elements, Maintenance/service – EUCHNER RPS User Manual
Page 13: Exclusion of liability

Operating Instructions for Rope Pull
Switches RPS...
13
Switching elements
The values for the tensile force depend on the switch type used. (RPS...100/RPS...175/RPS...300)
Tolerance: tensile force ± 15%
3131 (standard)
2131
Detent
Detent
Detent
Detent
3131 RPS-M (optionally with pre-failure monitoring)
ON OFF
S1
S2
Maintenance/service
In order to ensure trouble-free, long-term operation, it is necessary to perform regular, documented inspection
of the following:
-
smooth
actuation
-
correct switching function
-
Correct rope tension
-
secure mounting of components
-
dirt and wear
-
sealing of cable entry
-
loose cable connections or plug connectors.
After servicing or repair, correct functioning of the system should be checked by actuating the pull rope several
times. It must be ensured that the switch latches properly after actuation.
In the event of a fault in the switching system or latching device, the switch must be replaced and can be sent
to EUCHNER GmbH + Co. KG for inspection.
Exclusion of liability
If the instructions (incorrect use, safety regulations, mounting and connection by trained personnel, check for
safe function) are violated, this renders the manufacturer’s liability null and void.