2 keyboard setup in dvr, 3 configuration diagram iii, Max 16 dvr – EZWatch CMS software for TurboView User Manual

Page 117: Max 16 camera

Advertising
background image

117

13.1.3 Configuration Diagram III

Multiple system configuration (Multi Cameras, Multi DVRs)

Please make sure to connect “Tx to Rx “or “Rx to Tx” with positive polarity. (+ to +) and (- to -).


13.2 Keyboard Setup in DVR

Enter “Setup>SYSTEM>Information: System ID” and define the ID of DVR.

When user connects more than two DVRs then each DVR has to have a different ID.

Then move to “Setup>Device>Camera/PTZ: Keyboard” and select CP1200A.

Then, choose PTZ protocol and Camera ID.

Tx+

Tx-

Rx+

Rx-

DVR 1

RS485

+

RS485

-

Tx1

Tx1

Tx2

Tx2

Tx3

Tx3

TRx

TRx

Tx+

Tx-

Rx+

Rx-

DVR 2

Tx

+

Tx

-

Tx

+

Tx

-

Tx+

Tx-

Tx+

Tx-

Max 16 DVR

RS485

+

RS485

-

Tx+

Tx-

Tx+

Tx-

Tx+

Tx-

Tx+

Tx-

Max 16 camera

Multi port

Rx+

Rx-

Rx+ Rx-

Rx+

Rx-

Multi port

Rx+

Rx-

Rx+

Rx-

Rx+

Rx-

Advertising