1 control sections and connections, 2 function and application, 2function and application – Festo DGC-HD User Manual
Page 18

DGC-HD
18
Festo – DGC-HD – 1304NH English
1
Control sections and connections
1
3
4
2
5
6
7
8
9
aJ
aA
1 Shock absorbers (2x)
2 Guide rail (2x)
3 Lubrication hole for bearing guide (4x)
4 Thread and centring hole for mounting the
effective load (12x)
5 Slide
6 Thread for optional switch lug (on both
sides, 2x)
7 Supply ports
8 Surface for profile mounting
9 Slot for slot nut mounting and accessories
(on both sides)
aJ Groove for proximity switch (on both sides)
aA Supply ports with plug screws
Fig. 1
2
Function and application
When the compressed air ports are pressurised alternately, the internal slide moves backwards and
forwards in the cylinder barrel. By means of a rigid connection, the slide
5 also moves. The slot in the
cylinder barrel required for this is covered by a band system. The slide is bearing mounted. The refer-
ence position of the slide can be detected using proximity sensors in the slots
aJ.