Dimensions and Installation

4.5.1

Heat Retaining Plate Installation

The Heat Retaining Plate is to be flush-mounted. A support frame or support structure has to be custom designed
and built for housing the retaining plate(s).

4.5.1.1

Dimensions: RTCSmp HO IN800/1600/2400/3200 Heat Retaining Plate
(Measurements in mm and [inch])

4.5.1.2

Cut-Out Dimensions

 Please review carefully the dimensions in section 4.4.1.1.

 Refer to Detail A in section 4.4.1.1:

A. Cut-out dimension on the counter surface: 528 x 328 mm [20.79” x 12.91”]

NOTE:

Dimensions include widths for silicone joints on all four (4) sides.

Consider adjusting cutout dimensions based on mounting methods, see 4.5.1.3.

B. Recommended recess depth: minimum 8.00 to 8.64mm [0.315”to 0.34”]

C. Body Clearance (width x depth x height): 300 x 500 x 100mm / 11.81” x 19.69” x 3.94”