Installation

RTCSmp

Built-In

Temperature Controlled Hold-Line


Part # 4532287 Rev 4 (6/10/14)

17

4.6

Electrical Installation

IMPORTANT

 Refer to the electrical specifications in chapter 3 Dimensions and Technical Specifications AND the

markings/instruction labels on the unit. If the information differs between the data listed in the

manual and the markings on the unit, always follow the markings on the unit.

 Check and ensure that the supply voltage and the line current match the specifications given on the

rating plate. A stable mains supply must be provided.

CAUTION

Wrong voltage will damage the induction unit. Follow strictly

the specifications on the rating plate.

 The electrical connections must satisfy the national and local electrical codes.

 If ground fault current protective switches are used, they must be provided with selective activation and

designed for a minimum fault current of 30mA. Multiple generators with a mains connection must not be

connected to a single fault current protective switch.

 Always route sensor and communication cables separately and away from the coil cables.

 To manage electromagnetic interference, excess cable length can be dressed and tied in a serpentine or

S pattern, NOT coiled.

To setup the unit for operation:

1. Ensure the control knob is at the OFF-Position.

ON-Position
Any position where
“0”/Line is not pointing
straight up.

OFF-Position

“0” / Line is pointing
straight up.

2. Remove all objects from the glass cook-top and check that the glass cook-top is neither cracked nor

broken.

CAUTION

Do not continue if the glass cook-top is cracked or broken.
Contact an authorized service agency for assistance.