3 induction generator installation – Garland HO IN 3200 INDUCTION TEMPERATURE CONTROLLED BUILT-IN HOLD-LINE User Manual

Page 15

Advertising
background image

Installation

RTCSmp

Built-In

Temperature Controlled Hold-Line


Part # 4532287 Rev 4 (6/10/14)

15

4.5.2.2

Front-Mount

To mount the control unit

onto the front of the panel:

1. Drill holes and make the

cut-out using the
dimensions and the actual
unit provided.

2. Secure the control unit to

the panel with fasteners.





Illustration: Measurements in mm
and [inch].

4.5.2.3

Back-Mount

NOTE For this type of installation, the maximum thickness of the panel must not exceed 3mm or 12 gauge.

This restriction ensures a proper grip on the knob.

To mount the control unit

from the back of the panel:

1. Drill holes on the panel using

the dimensions provided.

2. Remove the plastic knob

from the control unit and
attach the control unit to the
panel with fasteners as

shown. NOTE: DO NOT

remove or loosen any

screws on the control unit.


Illustration: Measurements in mm
and [inch].

4.5.3

Induction Generator Installation

IMPORTANT

 All connectors are located at the FRONT of the Generator.

CLEARANCE minimum 2.95”(75mm) in front of the connectors.

 Ensure the generator and connectors can be accessed easily for electrical installation and service.

CLEARANCE minimum 1.57” (40mm) in front of the air-intake/exhaust outlets.

Front Panel

Front Panel

12 [ .474]

10.11 [ .398]

maximum

3 [0.12]