info@geodesy-fso.


• Power up the heads!

Receiver Alignment

• After a few seconds unplug the plugs of the motor controllers on both sides!

The motor control is a “light-buffer” this saves the power for the bad weather and in
the same time protects the receiver against overload. During the alignment it can be
used manually, to avoid the saturation, and keep the detector voltage on the level
where it can be still monitored. The detector voltage can be increased to seven volts;
above seven volts you won’t be able to monitor the detector voltage. This plate is
located in front of the receiver, and you can rotate it (clockwise decreases the
detector voltage, counter-clockwise increases).

• Follow the steps below

1

Switch on one of your transmitter on one side, and switch off all the others.
Switch off the transmitters on the other side too.

Orders of the switches:
You can check which transmitter is in use, after you switched on one of the
switchers, with the green LED on the back of every transmitter. Each LEDs are
indicates if them transmitters are functioning, and transmitting.

2

Move the head with the off switched transmitters until you can get the
biggest incoming light efficiency on the other side.

3

Fix the head as hardly as you can!

4

Repeat this with the other head too.