If you have a TC head

You can find a two sided fibre
connector in your ODIU. You have to
connect the fibre cable of your head
into the one side of the connector, and
into the other side you have connect
the fibre cable of you network
equipment (switch; router or GD
combiner). The fibre plugs of the
heads are always SC typed, which
means that them cross-sections are
cubic form. The fibre connector in the
ODIU is SC-SC typed, so you have to
provide an SC fibre plug for you

network. The SC-SC connector is a reversible part, so you can connect in the first
plug where you want, the important is that the two plugs of the head have to be on
one side, and the two plugs of the network have to be on the other, and if you plug in
the transmitter side of the head into a connector, then the transmitter side of the
network have to be in the opposite connector of the previous, and do the same with
the other sides too.

9.4.6 Connecting to the management

If you have a TP head

Using the RJ11 Sevice Connector you
can connect your management indoor
unit to the head, and you can measure
the detector voltage of the receiver of
the head as well.

More details about the management
please find to see its own Users’
Manual.