33

 Check the phone cord connection. Make sure that the jack

on the modem labeled Line is connected to an analog phone
wall jack.

 The modem cannot recognize the dial tone. This is typical in

some corporate PBXs. Use the ATX1 command in your
setup string to enable Blind Dial.

The modem does not answer an incoming call

 Auto-answer function is disabled. Enable the function

through software program or by sending the ATS0=1
command to your modem in terminal mode.

The modem disconnects while online

 This may be caused by line interference. Retry the

connection by dialing the numbers several times.

 An incoming call may have broken the connection if the

Call-waiting feature is enabled. Disable Call-waiting and

try again.


Garbage characters display on the monitor

 Set your modem to the same word length, parity, and stop

bits as the remote modem.

 Make sure that your software and modem are set to the

same flow control setting.