7 input and output details, 1 relays – INFICON XTC/C Thin Film Deposition Controller User Manual

Page 79

Advertising
background image

3 - 15

IP

N 07

4-

18

3X

XTC/C - XTC/2 Operating Manual

3.7 Input and Output Details

3.7.1 Relays

WARNING

The relay, relay circuit, and associated pins in the I/O
connector(s) have a maximum voltage rating of
30 V(dc) or 30 V(ac) RMS or 42 V(peak). The maximum
current rating per connector pin or relay contact is
2.5 Amps.

Their function is as follows:

Table 3-3 System I/O Connector

Relay #

Pin #

Function**

Closed Contacts

Open Contacts

1

1,2

Source Shutter 1

During Deposit and
Manual states when
source 1 is designated.

Balance

2

3,4

Source Shutter 2

During Deposit and
Manual states when
Source 2 is
designated.

Balance

3

5,6

Sensor Shutter 1

During the following
states when the
designated sensor is
active:

Balance
Balance

4

7,8

Sensor Shutter 2

- RateWatcher Sample

- Deposit

- Manual

- CrystalSwitch to dual

head backup

- Pulses during

CrystalSix transitions

- Shutter delay

Advertising