Intelix DIGI-DVI-F User Manual

Page 3

Advertising
background image

Symptom Probable

Causes

Possible

Solutions

No video

No continuity in video
link

Verify cable continuity between pairs of
baluns.
Verify the max distance has not been
exceeded.

No video

Power off

Check power supplies of video
equipment.

No signal

Improper connection or
swapped pairs

Check that baluns are connected to
correct video inputs and outputs.
Verify both ends of the twisted pair cable
conform to the EIA 568B crimp pattern.

Unusual colors
Rolling signal
Horizontal video
bars

Improper grounding or
cable type

Verify the source and destination devices
are grounded. Different electrical circuits
may cause a voltage differential on the
building’s electrical ground plain. The
video display or source deceive may need
to be grounded.

Background
pattern

EMI interference

Identify possible radiating frequency
sources (i.e.; wireless LANs, switching
power supplies) and isolate them.
Replace any unshielded twisted pair cable
with shielded twisted pair cable.

Advertising