15

4 Electrical connection

4.1

Safety information

•

The electrical connection must only be carried out by qualified personnel.

•

When mounting, connecting, and operating the transmitter, ensure that no electrostatic
charging can take place.

•

The transmitter is not suitable for installation and application areas with an explosion haz-
ard.

•

Never expose the transmitter to magnetic or electrical fields (e.g. caused by transformers,
walkie-talkies, or electrostatic discharge).

•

An electrical connection that deviates from the connection diagram can destroy the trans-
mitter.

•

The transmitter is suitable for use in SELV or PELV current circuits according to protection
rating 3. The case implements basic insulation of up to 50 V towards neighboring devices.

4.2

Terminal assignment and dimensions (mm) of
dTRANS T05 B

5
Ш

44
Ш

7

Ш

33

21

Connection for

Terminal assignment

Voltage supply

Type 707050

R

B

= (V

b

- 11 V)/22 mA

DC 11 to 35 V

Current output

R

B

= Load resistance

4 to 20 mA

V

b

= Voltage supply

2

1

+

–

Advertising