English, Vdv scout, Pro 2 lt – measuring length – Klein Tools VDV501-823 User Manual

Page 6: Pro 2 lt – displaying length constant, Pro 2 lt – length constant edit mode, Pro 2 lt – determining length constant, Pro 2 lt – changing unit of measurement

Advertising
background image

6

ENGLISH

VDV SCOUT

®

PRO 2 LT – MEASURING LENGTH

Measured Length = 45 ft.

Length Measurement Mode

Test Running Continuously

Cable Type

VDV SCOUT

®

PRO 2 LT – DISPLAYING LENGTH CONSTANT

1.

Assure the tester is off and the screen is blank.

2.

Press the length button

I

to enter length mode.

to enter length mode.

3.

Press the length button

I

again.

again.

The length constant will be displayed

on the screen for three seconds.

VDV SCOUT

®

PRO 2 LT – LENGTH CONSTANT EDIT MODE

Follow these instructions to set the length constant based on a known value (for example, as given by the cable manufacturer).

The VDV Scout

®

Pro 2 LT stores a separate length constant for each of the three cable types (voice, data, and video).

®

®

1.

Follow the procedure in

MEASURING LENGTH

section

MEASURING LENGTH

MEASURING LENGTH

to set up the correct type of cable.

2.

Press and hold the length button

I

for three seconds until EDIT CAP is shown

for three seconds until EDIT CAP is shown

on the screen.

3.

Press the Up Arrow

F

and Down Arrow

and Down Arrow

G

to increment or decrement the length constant

to increment or decrement the length constant

in units of 0.1pF to the desired

value. The screen will switch back and forth between

the length measurement and the length constant value

every two seconds while no buttons are pressed.

4.

Press the length button

I

again

again

to return to length measurement.

VDV SCOUT

®

PRO 2 LT – DETERMINING LENGTH CONSTANT

Follow these instructions to set the length constant based on a sample cable of known length. For best accuracy, the sample cable

should be 50 ft. or greater.
1.

Cut or obtain a length of cable of the same type you would like to measure. Measure the cable using standard methods (pad

printing on the cable or a tape measure).

2.

Follow the procedure in

MEASURING LENGTH

section

MEASURING LENGTH

MEASURING LENGTH

to set up the cable to be tested.

3.

Press and hold the length button

I

for three seconds until EDIT CAP is shown

for three seconds until EDIT CAP is shown

on the screen.

4.

Press the Up Arrow

F

and Down Arrow

and Down Arrow

G

to increment or decrement the length constant

to increment or decrement the length constant

in units of 0.1pF. The screen will

switch back and forth between the length measurement and the length constant value every two seconds while no buttons are

pressed. Press the arrows until the length measurement is the same as the value measured earlier. The length constant can

still be changed while the length measurement is being viewed in this mode.

5.

Press the length button

I

again to return to

again to return to

length measurement. You may now measure

other unknown lengths of cable.

VDV SCOUT

®

PRO 2 LT – CHANGING UNIT OF MEASUREMENT

1.

Assure the tester is off and the screen is blank.

2.

Press the length button

I

to enter length mode.

to enter length mode.

3.

Press the phone button

F

and video button

and video button

G

at the same time.

at the same time.

The screen will show "METERS" or "Ft." momentarily, then

show the length measurement in the unit selected.

Note: Ft. unit readings have no decimal place and are displayed as "0 Ft.". Meters unit readings have one decimal place and are displayed

"0_0" for 0.0 meters. Length constants are displayed in pF/ft. or pF/m depending on the selected unit measurement mode.

Length Constant = 15.0pF/ft.

Length Constant Display Mode

Length Constant = 15.0pF/ft.

Length Constant Edit Mode

Measured Length = 86 ft.

Length Constant Edit Mode

Pair of Wires Under Test