Landoll 876 Series Wing Tilloll User Manual

Page 25

Advertising
background image

ASSEMBLY INSTRUCTIONS

3-9

Hydraulic Lift Installation
(876-30, 876-35, 876-40-C)

IMPORTANT

Read all safety precautions at the front of the section
before attempting any of the following procedures.

1.

Install stroke control and stroke control cover on
master cylinders. Replace cylinder yokes. Adjust
cylinder extended length of all cylinders to measure
28-1/4" from hole center to hole center. Tighten lock
bolt or set screw to lock yoke in place.

NOTE

Always adjust the slave cylinder extended length to
measure the same as the master cylinder to allow the
unit to operate level in the field (See Table 3-1
and
Figure 3-6.)

2.

Install the master cylinders on the main frame ports
up, using clevis pin and cotter pins. Connect rod to
gauge wheel arm or rockshaft using extended pin
and 1/4 hair pins.

3.

Install the slave cylinders on the wing frame ports up,
using clevis pin and cotter pins. Connect rod to
gauge wheel arm or rockshaft using extended pin
and 1/4 hair pins.

4.

Install 90

o

adapters into base and rod end of each lift

cylinder.

5.

Install two 90

o

adapters in ports #2 and #4 and

adapter in port #3 of flow divider valve. Secure flow
divider valve to flow divider mounting bracket using
5/16-18 x 3 hex head cap screws, flat washers, and
hex lock nuts. Install check valves on frame using
3/8-16 x 1-3/4 hex head cap screws and split lock
washers.

IMPORTANT

Mount double pilot check valves so that the ports V1
and V2 are facing the flow divider valve with V1 port
behind the V2 port. Install hose A in V1 ports of each
check valve and connect to 90

o

adapters on the flow

divider valve. Install hose a into V2 port of each
check valve. Connect together hose A with tee
adapter.

6.

Screw check valve w/ orifice into port C1 of check
valves with arrow pointing away from port C1.

7.

Screw adapters into ports C2, V1, and V2 of check
valves. Use hose C to connect check valve w/ orifice
to base port of master cylinders.

8.

Connect hose B from adapter in C2 port of check
valves to the rod end of slave cylinders.

9.

Connect hose D from the base end of slave cylinders
to the rod end of master cylinders.

10. Install one hose E from tee adapter to coupler. Install

other hose E from adapter in port #3 in flow divider
valve to coupler.

IMPORTANT

All cylinder ports are plugged. Do not forget to
remove all plugs and replace with hoses or fittings
before applying hydraulic pressure to cylinders.

Table 3-1: Hydraulic Lift Hose Installation (876-30, 876-35, 876-40-C)

ITEM

PART NO.

HOSE LENGTH (MODEL USED)

A

71508984

3/8 X 42 (ALL MODELS)

B

116435

3/8 X 146 (876-30)

153621

3/8 X 212 (876-35)

71510821

3/8 X 244 (876-40-C)

C

71508992

3/8 X 50 (ALL MODELS)

D

141881

3/8 X 136 (876-30)

141882

3/8 X 206 (876-35)

71600088

3/8 X 228 (876-40-C)

E

156964

1/2 X 204 (ALL MODELS)

Advertising