2 general data and operating conditions, General data and operating conditions, Technical data – Lenze SDSGA User Manual

Page 15

Advertising
background image

Technical data

General data and operating conditions

3

l

15

BA 13.0008 − EN 2.1

3.2

General data and operating conditions

Field

Values

Conformity

CE

Low−Voltage Directive (73/23/EEC)

Climatic conditions

Average relative humidity 85 %, without condensation

Permissible
temperature range

Non−ventilated or with integral
fan without brake or with
spring−operated brake

−20 °C ... +40 °C Without power derating, above

+40 °C with power derating see
catalog

Protection type

See nameplate

Protection types only apply for
horizontal installation

Thermal class

F (155 °C) to DIN−IEC 34 / VDE 0530

The insulation will be weakened or
destroyed when the limit
temperature is exceeded

Tropical insulation

Not guaranteed

Permissible voltage

1.5 kV peak value

5 kV/

ms rate of rise

Vibration

Up to 2.0g / 20m/s

2

without resonance excitation, e.g. of the fan.

Mounting positions

Can be used in all mounting positions

Vertical arrangements to DIN−IEC
34 part 7 are possible if they meet
the designs
Motors with directly mounted
gearbox must not be mounted in
mounting position with motor at
the bottom

Permissible installation
height h

h

£ 1000 m amsl

1000 m amsl < h

£ 4000 m amsl

Without power derating
With power derating, see catalog