1 table of lubricants, Table of lubricants, Electrical installation – Lenze SDSGA User Manual

Page 22: Stop

Advertising
background image

Electrical installation

Gearbox mounting
Table of lubricants

5

l

22

BA 13.0008 − EN 2.1

Worm gearbox type SSN

SSN gearbox

SSN40 gearbox

0

1

2

51

52

M13.0142

SSN40GK−026

Fig. 2

Worm gearbox

0 Solid shaft design with flange

1 Solid shaft design without flange

2 Hollow shaft design

(

Stop!

After the shaft seal (51) has been mounted, mount the worm. Ensure stability
of the motor shaft end when pinning (50).

Use the screws and washers in the assembly kit for the motor to mount the gearbox to the
motor:

5.2.1

Table of lubricants

Gearbox type

Type of lubricant

Quantity [ml]

SSN31−1FVAL

CLP PG460

60

SSN31−1FVAR

40

SSN31−1FDAR

40

SSN31−1FHAR

40

SSN40−1FVAL

120

SSN40−1FVAR

80

SSN40−1FDAR

80

SSN40−1FHAR

80

Advertising