EDS84AYCER EN 2.0 - 11/2010
L
61
E84AYCER communication manual (PROFINET)
Parameter data transfer
Writing parameters to the controller
Parameter response after a correct write request
Parameter response after write error
Byte 1
Byte 2
Byte 3
Byte 4
Request reference
Response identifier
Axis
Number of indices
0xXX
0x02
0x00
0x01
(mirrored)
Parameter written
(mirrored)
1 index
Byte 1
Byte 2
Byte 3
Byte 4
Request reference
Response identifier
Axis
Number of indices
0xXX
0x82
0x00
0x01
(mirrored)
Parameter not written
(mirrored)
1 index
Byte 5
Byte 6
Format
Number of values
0x44
0x01
Error
Error code without additional
information
Byte 7
Byte 8
Error code
High byte
Low byte
For meaning see chapter "