Diagnostics

LED status displays

8

EDK94AYCET DE/EN/FR/ES/IT 5.0

41

l

H1_Diagnose−status_LEDs_E94AYCET

8

Diagnostics

LED status displays

For fault diagnostics the LEDs on the front are provided for the EtherCAT module.

)

Note!

During normal operation ...

ƒ

only the LEDs "MS" and "BS" should be lit constantly.

ƒ

The green LED at the RJ45 sockets X246 and X247 must be lit or blinking.

E94YCET001E

LED

Description

Pos.

Colour

Condition

MS

green

on

The communication module is supplied with voltage and has a
connection to the standard device.

blinking

200 ms

200 ms

The communication module is supplied with voltage but has no
connection to the standard device (standard device is either
switched off, in the initialisation phase, or not available).

ME

red

on

An error in the communication module has occurred.