Electrical installation

Important notes

6

l

45

EDK94ZMR47XDB DE/EN/FR/ES/IT 4.0

6

Electrical installation

6.1

Important notes

ƒ

Installation must
– always be in accordance with the operating conditions specified in the Technical

data (

36).

– be carried out to EN 60204−1.

ƒ

Please observe the following when selecting the cable type:
– The cables used must comply with the approvals required for the application (e. g.

VDE, UL etc.).

– Fuses and cable cross−sections must be dimensioned in accordance with the

specifications in the documentation for the basic device.

ƒ

The described EMC properties are provided if the following conditions are complied
with:
– The devices are mounted according to the arrangement concept described.
– The prepared cables are used and remain unchanged.

{

Danger!

Dangerous electrical voltage
All power terminals remain live for up to three minutes after mains
disconnection.
Possible consequences:

ƒ

Death or severe injuries when touching the power terminals.

Protective measures:

ƒ

Switch off the power supply and wait for at least three minutes before
working on the power terminals.

ƒ

Make sure that all power terminals are deenergised.